2023-10-16 How to fix the control system of shuttleless loom1. The electric control cabinet is damp and the circuit board is scorched.The electric control cabinet is damp and the circuit board is scorched.Solution: The electric control cabinet regularly replaces the full amount of the desiccant, avoids long-te
Read More
2023-10-16 Resolution for take-up part problemsProblems that may occur in the take-up part1.The take-up chain is broken. Solution:A. Adjust the pressure of 24CA-71 chain and tension link;B.Check if the 24CA-27Y auto-rotating wheel is normal or reverse;2. The stripper off. Solution to the problem: ensure that t
Read More
2023-10-13 Trouble resolution of beating up shaft part and let-off part1. Beating up shaft partIt's easy to accumulate waste yarn at the waterproof shield od the swing shaft, causing damage to the bearing, which results in poor beating with abnormal noises and the machine stops cloth defects. Please refer to t
Read More
2023-10-13 Troubleshooting and solution of opening device and weft insertion part Opening device:The cleaning cycle of the loom in use is 20-25 days each time, and the lithium grease filling cycle is 20-25 days each time, and ensure that the old oil can be extruded.the problem that often occurs in the opening